BOBCAT S130 – HYDRAULIC CONTROL VALVE (ACS) OR (SJC) – Check Valve Removal And Installation

Remove the tubeline (Item 1) [Figure 20-41-102].

Remove the check valve fitting (Item 1) [Figure 20-41-103] from the hydraulic control valve.

Installation: Lubricate the O-ring (Item 1) [Figure 20-41-104] and tighten the fitting to 20 – 24 ft.-lb. (27 – 33 N•m) torque.

Inspect the screen (Item 1) [Figure 20-41-105].

 

Leave a Reply

Your email address will not be published. Required fields are marked *