BobCat 753 – REGULAR MAINTENANCE – Filter Elements Removal And Installation

Remove the two mount bolts (Item 1) [Figure 80-20-1] & [Figure 80-20-2] from the fresh air filter cover at the rear of the loader cab.

Remove the filter cover and filter (Item 1) [Figure 80-20-3] & [Figure 80-20-4] from the loader.

Remove the filter (Item 1) [Figure 80-20-5] & [Figure 80-20-6] from the cover.

The fresh air filter must be cleaned sometimes as often as twice a day, depending on the operating environment. The filter can be cleaned by removing and shaking it. A small amount of air pressure can be used to clean the filter. However the fresh air filter should be changed at least 2-4 times per year in normal conditions. In extremely dusty conditions the fresh air filter may need to be changed weekly.

Remove the two retaining knobs (Item 1) [Figure 80-20-7] from the recirculating air filter cover, at the back of the cab.

Remove the retaining cover (Item 2) [Figure 80-20-7] from the loader cab.

Remove the recirculating air filter (Item 1) [Figure 80-20-8] from the rear of the cab.

The recirculating air filter [Figure 80-20-9] is made of open cell foam and should be cleaned with water. A mild detergent may also be used. It does not require cleaning as frequently as the fresh air intake filter.

Reverse the removal procedure to install the filter element.

 